Datasheet

1
G3VM-61GR2
MOS FET Relays
MOS FET Relays with 1.7-A switching
Designed for Switching Minute Signals
and Analog Signals.
Continuous load current of 1.7 A.
Application Examples
Terminal Arrangement /Internal Connections
List of Models
* The AC peak and DC value are given for the load voltage.
Absolute Maximum Ratings (Ta = 25°C)
Electrical Characteristics (Ta = 25°C)
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
Semiconductor test equipment
Test & Measurement equipment
Communication equipment
Data loggers
43
12
OMRON logo
Pin 1 mark
Model name
LOT.No.
932
Mold pin mark *
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
Package type Contact form Terminals
Load voltage
(peak value) *
Model
Minimum package quantity
Number per tube
Number per tape and reel
SOP4
1a
(SPST-NO)
Surface-mounting Terminals 60 V
G3VM-61GR2 100 -
G3VM-61GR2 (TR05) -500
Item Symbol Rating Unit Measurement conditions
Input
LED forward current IF 30 mA
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
LED forward current reduction rate
IF/°C 0.3 mA/°C Ta 25°C
LED reverse voltage VR 5 V
Connection temperature
TJ 125 °C
Output
Load voltage (AC peak/DC)
VOFF 60 V
Continuous load current (AC peak/DC)
IO 1.7 A
ON current reduction rate
IO/°C 17 mA/°C Ta 25°C
Pulse ON current IOp 5 A t = 100 ms, Duty = 1/10
Connection temperature
TJ 125 °C
Dielectric strength between
I/O (See note 1.)
V
I-O 1500 Vrms AC for 1 min
Ambient operating temperature
Ta 40 to +85 °C With no icing or condensation
Ambient storage temperature
Tstg 55 to +125 °C With no icing or condensation
Soldering temperature -260 °C10 s
Item Symbol
Minimum
Typical
Maximum
Unit Measurement conditions
Input
LED forward voltage VF 1.18 1.33 1.48 V IF = 10 mA
Note: 2. Turn-ON and Turn-OFF Times
Reverse current IR - - 10 µA VR = 5 V
Capacity between terminals
CT - 70 - pF V = 0, f = 1 MHz
Trigger LED forward current
IFT -0.63 mA IO = 100 mA
Turn-OFF LED forward current
IFC 0.1 - - mA IOFF = 100 µA
Output
Maximum resistance with output ON
RON -0.080.13
I
F
= 5 mA, I
O
= 1.7 A, t < 1 s
Current leakage when the relay is open
ILEAK - 1 10 nA VOFF = 60 V
Capacity between terminals
Coff - 250 - pF V = 0, f = 1 MHz
Capacity between I/O terminals
CI-O - 0.8 - pF f = 1 MHz, VS = 0 V
Insulation resistance between I/O terminals
RI-O 1000 10
8
-M
V
I-O
= 500 VDC, R
O
H
60 %
Turn-ON time tON -0.73ms
I
F = 5 mA, RL = 200 ,
V
DD = 20 V (See note 2.)
Turn-OFF time tOFF -0.10.5ms
VOUT
IF
tON tOFF
10%
90%
IF
1
2
4
3
RL
VDD
VOUT