Datasheet

4
G3VM-@BR@/@ER@ MOS FET Relays
DIP G3VM-@BR@/@ER@
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Spacing and Insulation
Item Symbol
G3VM-21BR
G3VM-21ER
G3VM-31BR
G3VM-31ER
G3VM-41BR
G3VM-41ER
G3VM-61BR
G3VM-61ER
G3VM-61BR1
G3VM-61ER1
G3VM-61BR2
G3VM-61ER2
G3VM-101BR
G3VM-101ER
G3VM-101BR1
G3VM-101ER1
Unit
Load voltage
(AC peak/DC)
V
DD Maximum 16 24 32 48 80 V
Operating LED
forward current
I
F
Minimum 5 10 5
mA Typical 10 10
Maximum 25 20 25
Continuous load
current
(AC peak/DC)
IO Maximum 4 5 3.5 2.5 3 4 2 3.5 A
Ambient operating
temperature
Ta
Minimum -20 -40
-20 -40 -20 -40
°C
Maximum 65 85
65
60 65 85
65 85
Item Minimum Unit
Creepage distances 7.0
mm
Clearance distances 7.0
Internal isolation thickness 0.4