Datasheet
5
G3VM-61BR/ERG3VM-61BR/ER
■ Absolute Maximum Ratings (Ta = 25°C)
■ Electrical Characteristics (Ta = 25°C)
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
■
Engineering Data
Load Current vs. Ambient Temperature
G3VM-61BR/ER
■
Safety Precautions
Refer to page 2 for precautions common to all G3VM models.
Item Symbol Rating Unit Measurement Conditions
Input LED forward current I
F
30 mA
Note 1. The dielectric strength between the
input and output was checked by
applying voltage between all pins as
a group on the LED side and all pins
as a group on the light-receiving
side.
Repetitive peak LED forward
current
I
FP
1 A 100 µs pulses, 100 pps
LED forward current reduc-
tion rate
∆I
F
/°C −0.3 mA/°CTa ≥ 25°C
LED reverse voltage V
R
5V
Connection temperature T
J
125 °C
Output Output dielectric strength V
OFF
60 V
Continuous load current I
O
2,500 mA
ON current reduction rate ∆I
ON
/°C −22 mA/°CTa ≥ 25°C
Connection temperature T
J
125 °C
Dielectric strength between input and out-
put (See note 1.)
V
I·O
2,500 Vrms AC for 1 min
Operating temperature T
a
−20 to 85 °C With no icing or condensation
Storage temperature T
stg
−40 to 125 °C With no icing or condensation
Soldering temperature (10 s) --- 260 °C10 s
Item Symbol Minimum Typical Maximum Unit Measurement conditions
Input LED forward voltage V
F
1.18 1.33 1.48 V I
F
= 10 mA
Note 2. Tur n - O N a nd Tur n -
OFF Times
Reverse current I
R
--- --- 10 µAV
R
= 5 V
Capacity between terminals C
T
--- 70 --- pF V = 0, f = 1 MHz
Trigger LED forward current I
FT
--- 1.0 3 mA I
O
= 1 A
Output Maximum resistance with out-
put ON
--- 0.065 0.1 Ω I
F
= 10 mA,
I
O
= 2 A
Current leakage when the re-
lay is open
I
LEAK
--- 1.0 10 nA V
OFF
= 60 V
Capacity between I/O terminals C
I·O
--- 0.8 --- pF f = 1 MHz, V
s
= 0 V
Insulation resistance R
I·O
1,000 --- --- MΩ V
I·O
= 500 V DC,
R
OH
≤ 60%
Turn-ON time tON --- 1.0 1.5 ms I
F
= 10 mA, R
L
= 200 Ω, V
DD
= 20 V (See note 2.)
Turn-OFF time tOFF --- 0.2 0.4 ms
IF
1
2
6
4
R
L
VDD
VOUT
IF
VOUT
tON
10%
90%
t
OFF
Item Symbol Minimum Typical Maximum Unit
Output dielectric strength V
DD
--- --- 48 V
Operating LED forward current I
F
10 --- 20 mA
Continuous load current I
O
--- --- 2,500 mA
Operating temperature T
a
25 --- 60 °C
3,000
2,500
2,000
1,500
1,000
500
0
−20
0 20 40 60 80 100
Load current (mA)
Ambient temperature (°C
)