Datasheet

4
G3VM-@AY@/@DY@ MOS FET Relays
G
3
V
M
@
A
Y
@
/
@
D
Y
@
I
D
I
P
Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
zStandard type
zHigh sensitive type
Spacing and Insulation
zStandard type and High sensitive type
Item Symbol
G3VM-41AY1
G3VM-41DY1
G3VM-61AY1
G3VM-61DY1
G3VM-201AY1
G3VM-201DY1
G3VM-351AY1
G3VM-351DY1
G3VM-401AY1
G3VM-401DY1
G3VM-601AY1
G3VM-601DY1
Unit
Load voltage (AC peak/DC) VDD Maximum 32 48 160 280 320 480 V
Operating LED forward current IF
Minimum 5
mA
Typical 7.5
Maximum 25
Continuous load current (AC peak/DC) IO Maximum 2000 500 250 100 120 90
Ambient operating temperature Ta
Minimum 20
°C
Maximum 65
Item Symbol
G3VM-41AY
G3VM-41DY
G3VM-61AY
G3VM-61DY
G3VM-201AY
G3VM-201DY
G3VM-351AY
G3VM-351DY
G3VM-401AY
G3VM-401DY
G3VM-601AY
G3VM-601DY
Unit
Load voltage (AC peak/DC) VDD Maximum 32 48 160 280 320 480 V
Operating LED forward current IF
Minimum 3
mA
Typical 5
Maximum 15 20
Continuous load current (AC peak/DC) IO Maximum 2000 500 250 100 120 90
Ambient operating temperature Ta
Minimum 20
°C
Maximum 65
Item Standard Unit
Creepage distances Minimum 7.0
mm
Clearance distances Minimum 7.0
Internal isolation thickness Minimum 0.4