Datasheet
3
G3VM-35@G@/351VY/401G@/401VY MOS FET Relays
G3VM-35@G@/351VY/401G@/401VYSOP
■Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
■Spacing and Insulation
Item Symbol G3VM-351G1 G3VM-351VY G3VM-353G G3VM-401G1 G3VM-401G G3VM-401VY Unit
Load voltage (AC peak/DC) VDD Maximum 280 320 V
Operating LED forward current IF
Minimum − 5 − 5
mA
Typical 2 7.5 − 0.5 7.5
Maximum 25
Continuous load current
(AC peak/DC)
I
O Maximum 80 110 120 80 120 110
Ambient operating temperature Ta
Minimum -20
°C
Maximum 65
100
65 100
Item
G3VM-35@G@/401G@ G3VM-351VY/401VY
Unit
Minimum
Creepage distances 4.0 5.0
mm
Clearance distances 4.0 5.0
Internal isolation thickness 0.1 0.2