Datasheet

2
G3VM-21UV11/51UV/61UV MOS FET Relays
G
3
V
M
2
1
U
V
/
5
1
U
V
/
6
1
U
V
I
V
S
O
N
(R)
■Absolute Maximum Ratings (Ta = 25°C)
* The dielectric strength between the input and output was checked by applying voltage between all pins on the LED side and all pins on the light-
receiving side.
■Electrical Characteristics (Ta = 25°C)
* Turn-ON and Turn-OFF Times
■Recommended Operating Conditions
To ensure highest reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics.
Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions.
Item Symbol G3VM-21UV11 G3VM-51UV G3VM-61UV Unit Measurement conditions
Input
Input forward voltage VIN 6V
Input reverse voltage VRIN 5V
Connection temperature TJ 125 °C
Output
Load voltage (AC peak/DC) VOFF 20 50 60 V
Continuous load current (AC peak/DC) IO 1,000 300 400 mA
ON current reduction rate ΔIO/°C −10 −3 −4mA/°CTa≥25°C
Pulse ON current lop 3,000 900 1,200 mA t=100 ms, Duty=1/10
Connection temperature TJ 125 °C
Dielectric strength between I/O * VI-O 500 Vrms AC for 1 min
Ambient operating temperature Ta −40 to +110 °C With no icing or condensation
Ambient storage temperature Tstg −40 to +125 °C
Soldering temperature − 260 °C 10 s
Item Symbol G3VM-21UV11 G3VM-51UV G3VM-61UV Unit Measurement conditions
Input
Reverse current IR Maximum 10 μAVR=5 V
Capacity between terminals CT Typical 30 pF V=0, f=1 MHz
Input forward current IF Typical 6.3 mA VIN=5 V
Operate voltage VFON
Typical 1.8
VI
ON=100 mA
Maximum 3
Release voltage VFOFF
Minimum 0.8
VI
OFF=10 μA
Typical 1.8
Output
Maximum resistance with
output ON
R
ON
Typical 0.18 1
Ω
V
IN=5 V, t<1 s,
I
O=Continuous load current ratings
Maximum 0.22 1.5
Current leakage when the relay
is open
I
LEAK Maximum 1 nA VOFF=Load voltage ratings
Capacity between terminals Coff
Typical 40 12 20
pF V=0, f=100 MHz, t<1 s
Maximum − 20 −
Capacity between I/O terminals CI-O Typical 1 pF f=1 MHz, VS=0V
Insulation resistance between I/O
terminals
R
I-O Typical 10
8
MΩ VI-O=500 VDC, ROH≤60%
Turn-ON time tON Maximum 2 0.5
ms
V
IN=5 V, RL=200 Ω,
V
DD=10 V (G3VM-21UV11)
V
DD=20 V (G3VM-51UV, -61UV)
*
Turn-OFF time tOFF Maximum 1 0.4 0.5
Item Symbol G3VM-21UV11 G3VM-51UV G3VM-61UV Unit
Load voltage (AC peak/DC) VDD Maximum 16 40 48 V
Operating input forward voltage VIN
Minimum 4
VTypical 5
Maximum 6
Continuous load current (AC peak/DC) IO Maximum 1000 300 400 mA
Ambient operating temperature Ta
Minimum −20
°C
Maximum 85
VOUT
VIN
tON t OFF
10%
90%
VIN
1
2
4
3
RL
VDD
VOUT