Datasheet
123
Text
122
Text
PCB Power Relay – G2R
Model Contact form Coil ratings Contact ratings
G2R-1 SPDT 3 to 110 VDC 10 A, 30 VDC (resistive)
G2R-14 3 to 240 VAC 10 A, 250 VAC (general use)
G2R-1-H TV-3 (NO contact only)
G2R-1-S
G2R-1-T
G2R-1A SPST-NO
G2R-1A4
G2R-1A-H
G2R-1A-S
G2R-1A-T
G2R-1-E SPDT
G2R-1A-E SPST-NO
G2R-2 DPDT 5 A, 30 VDC (resistive)
G2R-24 5 A, 250 VAC (general use)
G2R-2-H TV-3 (NO contact only)
G2R-2-S
G2R-2A DPST-NO
G2R-2A4
G2R-2A-H
G2R-2A-S
G2R-1A-ASI SPST-NO 10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-5/TV-8 (NO contact only), (For UL)
TV-8 (NO contact only); 1/4 hp, 125 VAC (For CSA)
■
Approved Standards
UL 508 (File No. E41643), CSA 22.2 No.14 (File No. LR31928)
16 A, 30 VDC (resistive, NO contact only)
16 A, 250 VAC (general use, NO contact only)
TV-3 (NO contact only); (1/3 hp, 120 VAC For UL)
PCB Power Relay – G2R
Double-winding Latching Relays
Item 1 Pole 2 Poles
Contact resistance 30 mΩ max. 50 mΩ max.
Set time 20 ms max
Reset time 20 ms max.
Min. set/reset signal width 30 ms max.
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 min 5,000 VAC, 50/60 Hz for 1 min
between coil and contacts*; between coil and contacts*;
1,000 VAC, 50/60 Hz for 1 min 3,000 VAC, 50/60 Hz for 1 min
between contacts of same pole; between contacts of different poles
1,000 VAC, 50/60 Hz for 1 min 1,000 VAC, 50/60 Hz for 1 min
between set and reset coil between contacts of same pole
1,000 VAC, 50/60 Hz for 1 min
between set and reset coil
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
(approx. 100G)
Malfunction: Set: 500 m/s
2
(approx. 50G); 200 m/s
2
(approx. 20G)
Reset: 100 m/s
2
(approx. 10G)
Endurance Mechanical: 10,000,000 operations min (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature Operating: -40˚C to 70˚C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 17 g (Quick-connect type: approx. 20g)
Note: Values in the above table are the initial values.
Power Relays
Omron 08 Cat 1-302 5/10/07 15:39 Page 122