Datasheet
* Input frequency; 500 Hz duty 40%, Input voltage; 5 V
Output voltage at no reflective object is defined as 0 mV.
The reference surface and mounting surface are shown in the following figure.
Measurement method of distance to reflective object
■ Engineering Data
Measurement data of distance characteristics for reference
■ Recommend sampling timing
I/O Timing
Mounting surface
L = 22.8mm
<Reflective object>
Black paper
Datum level
L = 70mm
<Reflective object>
White paper
100
90
80
70
60
50
40
30
20
10
0
0 20 40 60 80 100
Distance to reflective object (mm)
Vout (mV)
Black paper
White paper
PMMA plate
1600µs
V
out
t
Pulse
5V
Sampling
Timing
(OFF)
1000µs
Sampling
Timing
(ON)
1cycle = 2000µs
Output process = Vout (ON) − Vout (OFF)
V
out (ON)
Vout (OFF)
Sampling
Timing
(ON)
Sampling
500 Hz, duty 40%
Timing
(OFF)
OFF1200µs ON800µs
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. E443-E1-03
0416 (0815)(O)
Note: Do not use this document to operate the Unit.