User's Manual
5-4 Communication Commands
5-4
5-35
5-4-7 Polling Single Auto Read (PR)
Immediately after receiving the Polling Single Auto Read Command, the Reader/Writer returns a
response indicating the acceptance of the command, and waits for a Tag to enter the communications area
of the Antenna. Then it reads the data of the entering Tag. The host can inquire of the Reader/Writer
about the results of communications processing using the Polling Check (PC) command.
<Command Format>
STX
Node No..
Command code
“PR”
Data
type
Tag
type
First read
page
No. of
read
pages
ETX BCC
1 2 2 1 1 2 2 1 1
Data type Specifies whether the read data is represented in ASCII or HEX.
A : ASCII code
H : HEX code
* Refer to SECTION 5-3-6 Specifying a Data Code for details.
In ISO mode
Specify the Tag type.
A: I.CODE SLI chip
Tag
type
*
In I.CODE1
mode
Not added.
First read page Specifies the first page in hexadecimal to read data from the Tags.
Specification range: 00 to FFh (In ISO mode: I.CODE SLI chip
should be from 00 to 1Bh)
Specification range: FB to 0Ah (In I.CODE1 mode)
* Refer to SECTION 2-4 Memory Map of Tag for details.
No. of read pages Specifies the number of the pages in hexadecimal to read data from
the Tags.
Specification range: 01 to FFh (In ISO mode: I.CODE SLI chip
should be from 01 to 1Ch)
Specification range: 01 to 10h (In I.CODE1 mode)
* Tag Type Setting is valid in the operating mode setting range of Reader/Writer.
<Response Format>
STX Node No..
Retry
flag
Command code
“PR”
Response
code
“74”
ETX BCC
1 2 1 2 2 1 1
Response code 74: Command acceptance
For other Response Codes, refer to SECTION 5-3-7 Response Code List.