5-3
5-25
5-3-7 Response Code List
5-3-7-1 ISO Mode
Type
Response
Code
Name Description
“00” Normal completion
The received command ends normally with no error.
“72” Multi-processing end
Communications end response when a multi-trigger function is used.
“74” Polling command
received
Polling command has been received normally.
Polling Check is received before the completion of communications with a Tag.
“75”
Polling processing
canceled
Polling processing is canceled before the completion of communications with a
Tag.
Normal
completion
“76”
Polling processing
canceled
Polling processing is canceled after the start of communications with a Tag.
“10” Parity error
A parity error occurs in one of the characters of the received command.
“11” Framing error
A framing error occurs in one of the characters of the received command.
“12” Overrun error
An overrun error occurs in one of the characters of the received command.
“13” BCC error
The received command has an incorrect BCC.
“14” Format error
The command format is incorrect.
A stop command is received in command-waiting status.
An I.CODE1-mode specific command/function is executed.
Host
communica
tions error
“18” Frame length error
ETX is not received in 289 characters or less after STX is received.
“70” Communications
error
An error occurs during the communications with a Tag, and communications
cannot end normally.
“71” Write process error
Failed to write correct data onto a Tag. (Verification error)
An error occurred in the data writing process between a Tag,
preventing the process from being completed normally.
“72” No Tag error
No Tag is present in front of Antenna when a Trigger command is executed.
There are multiple Tags within the communications area when using Single
Access mode.
“79” Command error
Refer to the correlation table of ISO/IEC Error Codes.
“7A”
Address error
Unavailable pages. (ISO/IEC standard error code 10)
*Results in 79 error on I.CODE SLIs because the Tag is not supported.
Communica
tions error
“7E”
Lock error [ver1.20
and higher]
Writing onto a locked page. (ISO/IEC standard error code 12) *Results
in 79 error on I.CODE SLIs because the Tag is not supported.
“7C”
Communication
circuit error
An error occurred in the Reader/Writer communication circuit.
System
error
“93” Memory error
The EEPROM for the operating condition setting cannot be re-written
normally.
Correlation table of ISO/IEC Error Codes
When a Tag incorporating ISO/IEC chip (including I.CODE SLI chip) returns an error response, the
Reader/Writer responses a Response Code shown in the table below.
ISO code Description
Response code of module
01
An unadopted command. No request command can be
recognized.
79
02 An unrecognizable command. ex. format error.
79
03 An unadopted arbitrary command
79
0F An unaccountable error or unadopted error code.
79
10 A specific block cannot be use. (There is none)
7A
11
A specific block cannot be relocked since the block has
been already locked.
00
12 A specific block cannot be rewritten since it is locked.
71/7E
13 A specific block has not completed writing correctly.
71
14
A specific block has not completed locking correctly.
71
Others RFU 79