User's Manual

5-3 Command-Response Format
5-3
5-21
AC
Antenna
Changeover
Sets the antenna changeover in the Reader/Writer.
TM Terminal Resistance Sets the terminal resistance for RS485 in the Reader/Writer.
FL Offline Mode Setting
Sets which mode the Reader/Writer will start online or
offline.
IS
Initialization of
Setting
Reset the Reader/Writer to the factory settings.
EW Set Value Writing Stores the Reader/Writer set value on the EEPROM
TY
Chip Operating Mode
Switch
Switches I.CODE1/I.CODE SLI modes
MX
Duplicate
Communication
Protecting Setting
Enables/Disables Duplicate Communication
Protecting Function sets the number of the tables.
CA
I/O Automatic
Changeover setting
Enables/Disables I/O Automatic Changeover setting.
* In Offline Mode, the only commands accepted are Stop Command (ST) or Reset Command(XZ).
5-3-4 Communication Method List
The communication mode is set by specifying the following communication code as the
command-data option. The available communication modes vary, depending on the commands
or operation modes.
Name Code Description
Single Trigger ST Immediately after receiving a command, the Reader/Writer
communicates with a Tag and returns a response.
If the Tag is missing, an error (Code:72) is returned.
During communications, only one Tag should exist in the
communications area.
Single Auto SA After receiving a command, the Reader/Writer waits for a Tag to
enter the communications area. Next, the Reader/Writer
communicates with the entering Tag and returns a response. During
communications, only one Tag exists in the communications area.
Single Repeat
(ISO mode)
SR After receiving a command, the Reader/Writer waits for a Tag to
enter the communications area. Next, the Reader/Writer
communicates with the entering Tag and returns a response. After
sending the response, the Reader/Writer enters a Tag waiting state
again and repeats this process until receiving the Stop(ST) or Reset
Command(XZ).
During communications, only one Tag should exist in the
communications area.
This method is for ISO mode only. Do not specify this method in
I.CODE1 mode.
Multi-trigger MT Immediately after receiving a command, the Reader/Writer
communicates with all of the Tags existing in the communications
area and returns responses corresponding to each Tag.
If the Tag is missing, an error (Code:72) is returned.
Multi-repeat MR The Reader/Writer waits for Tags to enter the communications area.
It communicates with all of the Tags existing in the communications
area and returns responses corresponding to each Tag. After
completing communications, the Reader/Writer disables the operation
of the Tag. After sending the response, the Reader/Writer enters a
Tag waiting state again and repeats this process until receiving the
Stop(ST) or Reset Command(XZ).
FIFO Trigger FT Immediately after receiving a command, the Reader/Writer
communicates with a Tag and returns a response.
After completing communications, the Reader/Writer disables the
operation of the Tag. After sending the response, the Reader/Writer
will continue to operate until it receives a FIFO command, Stop(ST)
command, or Reset command(XZ)
.
During communications, only one Tag in the Communications area is
operable.
FIFO Auto
FA
After receiving a command, the Reader/Writer waits for a Tag to
enter the communications area. Next, the Reader/Writer