User's Manual
4-3 Reader/Writer Setting
4-3
4-9
4-3-5 Offline Mode Setting
Set whether the Reader/Writer will start in offline mode or online mode.
This setting can be made by using the offline mode setting command (FL)
Setting name
(command name)
Default set value
Setting
range
Offline Mode Setting
(FL command)
Enable (offline mode)
Enabled,
Disabled
EAS threshold
75%(4Bh)
25%(19h)
0-100%
(00h〜64h)
OUT1 output time 500 ms (05 h)
100ms-22.5 s
(01h〜FFh)
4-3-6 Initialization of settings
If necessary, you can return all the settings to their default set values.
Use the initialize settings command (IS) to return your settings to their
default set values
Setting name
(command name)
Initialize settings
(IS command)
4-3-7 Fixing of Settings
By fixing the settings that you have made using various setting
commands, you can write them into the EEPROM (nonvolatile memory)
so that they will survive a power reset of the Reader/Writer.
Use the EEPROM write command (EW) to fix your setting
Setting name
(command name)
EEPROM write
(EW command)
Precautions on setting modifications
● The execution of the setting commands only modifies the S-RAM (volatile memory) on the Reader/Writer. The
modifications are not reflected immediately; they are reflected only after the Reset Command (XZ) has been
executed.
● To apply the modified settings at the next startup, fix the settings and reset the power supply. If the settings are
not fixed, the modifications will be reset to the original status after the power supply reset. This does not apply to
the communication settings for COM2.
● If Reset Command (XZ) is executed without fixing the settings, the settings are reset to original status after the
power supply reset.
● The default mode is Offline mode. To change the settings, the mode must be switched to Online mode. Connect the
host and execute Stop Command (ST.)