1) Communications type setting for COM1 port
Set whether COM1 will be used as RS-232C or RS-485
by using the communications type setting command (CT)
Setting name
(command name)
Default set value Setting range
Communications
type setting *1
(CT command)
RS-232C
RS-232C
RS-485
2) Node No. setting
If more than one Reader/Writer is connected to a single host, each
Reader/Writer needs an ID number so that the host can discriminate one
Reader/Writer from another. Such an ID number is called node number.
Each Reader/Writer must be assigned a unique node number. Each
command or response includes the node number of the Reader/Writer.
Communications will not be possible if the node number is wrong.
The setting can be saved by executing the setting write command.
Use the node number setting command (NM) to set a node number.
Setting name
(command name)
Default set value Setting range
Node No. setting
(NM command)
00
0031
Communications through COM2 are possible regardless of the node
number setting.
3) Terminal resistance setting
This setting is necessary when COM1 is used as RS-485.
If more than one Reader/Writer is connected to a single host, terminal
resistance must be turned on for both the host and the Reader/Writer
connected to either end of the host in order to ensure stable operation.
The setting can be saved by executing the setting write command.
Use the terminal resistance setting command (TM) to set the terminal
resistance.
Setting name
(command name)
Default set value Setting range
Terminal resistance
setting
(TM command)
OFF ON/OFF
For more information, refer to 4-6-2-2 RS-485 Interface Cabling.
4-3-2 Chip Operating Mode Setting
This Reader/Writer consists of 2 types of operating modes (hereinafter
called: Operating Mode) in accordance with a type of the Tag (an
incorporated IC chip). Both operating modes must be set in accordance
with the Tag you choose. Execute the Operating Mode Switch Setting
Command (TY)
.
Setting name
(command name)
Default set value
Setting
range
Remarks
ISO
Mode
Conformed to the
ISO/IEC15693 standard
(I.CODE SLI Chip)
Operating Mode
Switch Setting
Command (TY)
ISO Mode [1.20 - ]*
I.CODE1 Mode
[ - 1.10]
I.CODE1
Mode
I.CODE1 Chip
supported