User's Manual
4-3 Reader/Writer Setting
4-3
4-5
The Reader/Writer has been designed for the user to make all the settings
by issuing commands from the host. The user can use either the COM1 or
COM2 port to make settings. However, we recommend use of the COM2
port because its communications settings have been fixed at factory to
survive a power reset.
In order to fix the information set for the Reader/Writer to survive a
power reset, it is necessary for the user to execute the setting write
command (EW) (refer to 10) in 5-7-14 of Section 5). (This does not apply
to the communications settings for the COM2 port).
4-3-1
Host Communications Setting (COM Port Setting)
Make settings for host communications by using the communications port
setting command (CP)
Setting name
(command name)
Port
Default set
value
Setting
range
Description
COM1 38400 bps
Baud rate setting *1
(CP command)
COM2 9600 bps
9600 bps
19200 bps
38400 bps
115200 bps
This command sets the baud rate for use in
communications with the host.
COM1 7bits
Data length setting *1
(CP command)
COM2 7 bits
7 bits
8 bits
This command sets the data length for use in
communications with the host.
COM1 Even
Parity bit setting *1
(CP command)
COM2 Even
None
Odd
Even
This command sets the parity bit for use in
communications with the host.
COM1 2bits
Stop bit setting *1
(CP command)
COM2 2 bits
1bit,
2 bits
This command sets the stop bit for use in
communications with the host.
COM1 Enabled
BCC bit setting *1
(CP command)
COM2 Enabled
Disabled
Enabled
This command sets whether the BCC for
command frames and response frames for
communications with the host will be enabled
or disabled. Using the BCC is referred to as
"BCC enabled."
COM1 No
ACK/NACK setting *1
(CP command)
COM2 No
No
Yes
This command sets whether or not ACK/NACK
control is performed between the host and the
Reader/Writer. If this control is not performed,
it is referred to as "no ACK/NACK control."
COM1 0.5 sec.
Timeout setting *1
(CP command)
COM2 0.5 sec.
0.5 sec.
5 sec.
This command sets the timeout period for
ACK/NACK control. This setting will be
meaningless unless this command
(ACK/NACK control) is set to ON.
:(*1) The communications settings for the COM2 port can also be
changed but will return to the Default set values on resetting the
power of the Reader/Writer.