User's Manual

2-2 Specifications
2-2
2-4
2-2-1 General Specifications
Item Specifications
Supply voltage 24VDC ±10%
Power consumption
27 W or less
Ambient operating
temperature
-10 to 50 (with no icing)
Ambient operating humidity 35% to 85% RH (with no condensation)
Ambient storage temperature -25 to 65 (with no icing)
Insulation resistance
20 MΩ min. (by a 100 VDC mega) between both
I/O terminals and both power supply terminals,
between both COM terminals, and between both
ANT terminals
Dielectric strength
Leakage current of 10 mA max. at 1000 VAC
(50/60 Hz) for 1 minute in any of the above
combinations
Vibration resistance
No abnormal condition after applying 10 sweeps
of a vibration of 10 to 150 Hz and 0.2mm double
amplitude in X, Y, and Z directions for eight
minutes
Shock resistance
No abnormal condition after giving an impact of
150 m/s
2
three times each in X, Y, and Z
directions, i.e., 18 times in total
Grounding Connecting to a ground of 100 or less
Dimensions 247 x 84 x 128 mm (W×H×D)
Protective construction IP60 (IEC60529 Standard)
Number of terminals for
antenna connection
Transmitting/receiving antenna: 1
Receive-only antennal: 1
Material Aluminum die casting
Mounting method Fastening with M6 screws
Standby time*1 15 min
Weight Approx. 1.6 kg
(*1) The time that elapses after turning power ON to getting stable for
communication.
2-2-2 Performance Specifications
Item Specifications
Self-diagnostics
CPU Error, System Error, Host communication
Error, Tag Communication Error.
Initialization process at power-on
During the initialization process after power-on, four LED indicators: RUN, COMM, NORM, and ERROR light up.
No commands are accepted during the initialization process (approximately 2.5 seconds).