7-1 Turn Around Time and Communication Time
7-1
7-3
The provided TAT graph data shows an example in which the V720S-BC5D4A Controller is used with the
following communications specifications for host communications: Data is continuously sent with no
space between characters, at a baud rate of 38,400 bps, in a data length of 7 bits with 1 start bit, 2 stop
bits and even parity . The number of bytes in case ASCII are specified as the data code.
The transmission rate of the Tag is set in Fast Mode as factory default.
2Communication time in
Multiple modes:
The communication time when the commands with multiple access options
are used varies depending on operating conditions. Those conditions
include the number of bytes, as well as the number of Tags in the
communication area. The mean values in consideration of these conditions
are shown in the table below.
Example of Multiple Access communication time: I.CODE1 Chip (msec)
2 pages (8 bytes) Read 2 pages (8 bytes) Write
Number of
Tags
Tag No.setting
Fast Mode Standard Mode Fast Mode Standard Mode
2 1 144 560 190 715
4 2 301 917 378 1139
8 3 644 1659 784 2016
16 4 1391 3239 1656 3867
The transmission rate of the Tag is set in Fast Mode as factory default.