5-9 Command Connection: I.CODE1 Mode only
5-9
5-66
This Command Connection works in I.CODE1 Mode Only, and does not support ISO Mode.
A command connection function allows the Reader/Writer to perform a pair of read and write operations
at a time by sending a command only once.
Any of the following six commands can be paired.
Read (RD) This excludes Special Read.
Write (WT)
Polling Single Auto Read (PR)
Polling Single Auto Write (PW)
Memory Check (MC)
Memory Calculation (MK)
Example of command connection
In a command connection function, a single STX, Node No., BCC and ETX are shared each, and connected
to each other using "+."
<Command Format>
STX Node No..
Command
(1)
Fixed
“+”
Command
(2)
ETX
BCC
1 2 1 1 1
<Response Format>
(1) When completed successfully
STX Node No..
Retry
flag
Response
(1)
Fixed
“+”
Response
(2)
ETX BCC
1 2 1 1 1 1
(2) When completed unsuccessfully
When a command has not completed successfully, the command code of the command (1) and a
response code are returned.
STX Node No..
Retry
flag
Command
(1) Code
Response
code
ETX BCC
1 2 1 2 2 1 1