User's Manual

5-5 System Command
5-5
5-44
5-5-5 EAS Setting (ES): I.CODE1 Mode only
This command sets the EASBit of a Tag incorporating I.CODE1 chip. When the EASBit is
disabled, the Reader/Writer will not return a response to the EAS Check Command (EA).
<Command Format>
STX
Node No..
Command code
“ES”
Setting ETX BCC
1 2 2 2 1 1
Setting
Specification range00to01
00:EAS enabled
01:EASdisabled
<Response Format>
STX Node No..
Retry
flag
Command code
“ES”
Response
code
“00”
ETX BCC
1 2 1 2 2 1 1
Response code 00:normal completion
For other Response Codes, refer to SECTION 5-3-7 Response Code List.
The relative commands are set in offline mode (refer to 5-7-12 FL Command). This command is
for I.CODE1 mode Only. The command is not available in ISO mode.
5-5-6 QuietBit Setting (QB): I.CODE1 Mode only
This command sets QuietBit of a Tag incorporating I.CODE1 chip. If you enable this bit, a Tag
ceases to return a response to any command (excluding the EAS Command).
<Command Format>
STX
Node No..
Command code
“QB”
Setting ETX BCC
1 2 2 2 1 1
Setting Specification range:00h to 01h
00: Disable QuietBit
01: Enable QuietBit
<Response Format>
STX Node No..
Retry
flag
Command
code
“QB”
Response
code
“00”
ETX
BCC
1 2 1 2 2 1 1
Response code 00:normal completion
For other Response Codes, refer to SECTION 5-3-7 Response Code List.
This command is for I.CODE1 Mode Only. The command is not available in ISO mode.