User's Manual
5-5 System Command
5-5
5-42
5-5-3 System Lock (SL): ISO Mode only
This command locks (write-inhibit) to write to system area information of a Tag.
<Command Format>
(1) Normal lock
STX
Node No..
Command code
“SL”
Tag
type
System
method
ETX BCC
1 2 2 1 2 1 1
(2) In a case where UID of a Tag is specified
STX
Node No..
Command code
“SL”
Tag
type
System
method
UID
ETX BCC
1 2 2 1 2 16 1 1
Tag type Specifies the Tag type.
A: I.CODE SLI chip
System method Specifies the system information to lock.
01:AFI
02: DSFID
03: EAS (normal lock)
83: Select EAS (In a case where UID of a Tag is specified and locked)
UID Specifies the UID of a Tag to lock in hexadecimal.
<Response Format>
STX Node No..
Retry
flag
Command
code
“SL”
Response
code
“00”
ETX
BCC
1 2 1 2 2 1 1
Response code 00:normal completion
For other Response Codes, refer to SECTION 5-3-7 Response Code List.
(Important) Precautions on the Lock function
Be careful that once system information has been locked, the lock cannot be cleared.
:This command is in ISO mode Only. The command is not available for I.CODE1 mode.