User`s manual

10355565_V_1_0.DOC
22/30
There are no servicable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuseholder on the rearpanel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
System specifications:
Power supply: 230 V AC, 50 Hz ~
Power consumption: 10 W
Fuse: T 0.5 A
Audio inputs/outputs: XLR, jack, screw terminals
Input impendance: 10/20 kOhms (unb./bal.)
Output impendance: 300/150 kOhms (unb./bal.)
Frequency response: 20 Hz - 20 kHz, ±3 dB
S/N ratio: > 95 dB, unweighted
Crosstalk: > 90 dB
Distortion: < 0.01 %
Frequencies: 25/40/63/100/160/250/400/630Hz/1k/1.6k/2.5k/4k/6.3k/10k/16 kHz
Equalizer section:
Frequency: variable (20 to 2 kHz)
Q (Quality): variable (30 to 3)
Control range: ±6 dB or ±15 dB
Low Cut: 30 Hz
Compressor section:
Threshold: variable (-40 to +22 dBu)
Ratio:
variable (1:1 to :1)
Attack time: variable (0.1 ms to 100 ms)
Release time: variable (0.1 sec to 2.5 sec)
Output:
variable (- to +6 dB)
Display:
Gain Reduction: VU Meter, 7 LEDs
Dimensions/Weight:
Dimensions (WxDxH): 483 x 210 x 44 mm
Weight: 3 kg
Please note: Every information is subject to change without prior notice. 06.09.2006 ©