User manual
STEELCABINET
Steel Cabinet
Safety Instructions
Assembly Steps
The steel cabinets of the SRT series serve to accommodate units of 483 mm (19") width. The cabinets
are equipped with a lockable door with acryl glass panel and removable side panels. A fan unit is
integrated in the roof. Amultiple socket outlet is included.
Maintenance and service operations are only to be carried out by authorized dealers. Damage caused
by manual modifications on this device is not subject to warranty.
If the steel cabinet and the fan unit is used for other purposes than originally intended, if it is not correctly
mounted, overloaded or not correctly connected, damage may result and the guarantee becomes void.
Avoid excessive humidity and heat. The recommended temperature range lies between -10° C and +40° C.
In order to prevent that the cabinet becomes top-heavy, heavy devices have to be mounted in the lower
part of the cabinet. The front plate of devices alone is not sufficient as a secure fastening. The devices
have to be additionally supported by side rails or a bottom carrier plate in order to reduce the pressure on
the front plate of the device and to minimize movements during transportation.
Additional space should remain above and below the devices in order to ensure sufficient ventilation and
to avoid overheating.
Caution, hazardous mains voltage! The fan unit is allowed to be operated with an alternating current
of 230 V AC, 50 Hz and was designed for indoor use only. This device falls under protection-class I.
The power plug must only be plugged into a protection class I outlet. The voltage and frequency must
exactly be the same as stated above. Wrong voltages or power outlets can lead to the destruction of
the device and to mortal electrical shock.
?
?
?
?
?
?
1. Mount the casters with screws M12 and the adjustment feet at the bottom of the base plate (fig. [1]).
2. Fix the four side posts with screws M8 to the base plate .
3.Attach the connecting panels with screws M6 to the side posts (fig. [3]).
4. Screw the rack rails with screws M6 to the connecting panels (fig. [4]).
5.Attach the roof with screws M6 to the side posts .
6. Install the carrier plate, cable holder and the multiple socket outlet.
7. Put each side door in the cutouts of the base plate (fig. [7]).
8. Put the front door in the cutouts of the base plate and the roof (fig. [8]). Remove the protective
foil on the front and rear sides of the acryl glas pane.
9. Connect the fan unit's power plug to a power outlet. With the power switch the fan unit can be switched
on and off.
Technical Specifications
1
AssemblyInstructions
1
2
1
3
2
2
7
5
6
1
1
4
00052555.DOC,Version1.0
100kg
MaximumLoad
30103288
100kg
6U
30103290
150kg
UseableHeight
30103294
10U
16U
Item
600x600x360mm
Dimensions
600x600x520mm
600x600x820mm
18kg
Weight
19kg
44kg
100kg30103292 12U 600x600x805mm 36kg
150kg30103300
150kg
20U
30103304
200kg30103330
28U
40U
600x600x1000mm
600x600x1360mm
600x600x2060mm
60kg
61kg
74kg
200kg30103320 35U 600x600x1820mm 55kg
www.omnitronic.com
EN
5
Please note: Every information is subject to change without prior notice. 10.03.2010 ©
3