Specifications

orDering inForMation
Page 3
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • info@omnitron-systems.com • 140 Technology Dr. Irvine, CA 92618
iConverter T1/E1
©2010 Omnitron Systems Technology, Inc. All rights reserved. iConverter and NetOutlook are registered trademarks of Omnitron Systems Technology, Inc.
Trademarks are owned by their respective companies. Specications subject to change without notice.
091-18700-003I 9/10
Model Type
Fiber
Type
Distance
Connector Types Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx Sen-
sitivity
(dBm)
Max. Rx
Sensitivity
(dBm)
Link
Budget
(dB)
ST SC MT-RJ LC SFP**
T1/E1
Copper RJ-48
Dual Fiber
- - - - - - 8719-0-x - - - - - - -
MM 5km 8700-0-x 8702-0-x 8704-0-x 8706-0-x - 1310 1310 -23 -12 -31 -12 8
SM 30km 8701-1-x 8703-1-x 8705-1-x 8707-1-x - 1310 1310 -15 -8 -31 -8 16
SM 60km 8701-2-x 8703-2-x - 8707-2-x - 1310 1310 -5 0 -31 -3* 26
SM 120km - 8703-3-x - 8707-3-x - 1550 1550 -5 0 -31 -3* 26
T1/E1
Copper RJ-48
Single-Fiber
SM 20km - 8710-1-x - - - 1310 1550 -15 -5 -30 -3 15
SM 40km - 8710-2-x - - - 1310 1550 -8 0 -30 -3* 22
SM 20km - 8711-1-x - - - 1550 1310 -15 -5 -30 -3 15
SM 40km - 8711-2-x - - - 1550 1310 -8 0 -30 -3* 22
Consult the diagramabove for standalone versions. Substitute the appropriate standalone version letter for the x in the model number.
For wide terperature (-40 to 60
o
C), add a “W” to the end of the model number. Consult factory for extended temperature (-40 to +75
o
C) models.
When using single-ber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.
*A minimum of 3dB of attenuation is required for these models.
**See SFP data sheet under Fast Ethernet for supported transceiver models.
Model Type
Fiber
Type
Distance
Connector Types Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
Min. Tx
Power
(dBm)
Max. Tx
Power
(dBm)
Min. Rx
Sensitivity
(dBm)
Max. Rx
Sensitivity
(dBm)
Link
Budget
(dB)
ST SC MT-RJ LC SFP
T1/E1
Copper RJ-48
Dual Fiber
- - - - - - 8719-0** - - - - - - -
MM 5km 8700-0 8702-0 8704-0 8706-0 - 1310 1310 -23 -12 -31 -12 8
SM 30km 8701-1 8703-1 8705-1 8707-1 - 1310 1310 -15 -8 -31 -8 16
SM 60km 8701-2 8703-2 - 8707-2 - 1310 1310 -5 0 -31 -3* 26
SM 120km - 8703-3 - 8707-3 - 1550 1550 -5 0 -31 -3* 26
T1/E1
Coax + RJ-48
Dual Fiber
(2-slot module)
- - - - - - 8739-0** - - - - - - -
MM 5km 8720-0 8722-0 8724-0 8726-0 - 1310 1310 -23 -12 -31 -12 8
SM 30km 8721-1 8723-1 8725-1 8727-1 - 1310 1310 -15 -8 -31 -8 16
SM 60km 8721-2 8723-2 - 8727-2 - 1310 1310 -5 0 -31 -3* 26
SM 120km - 8723-3 - 8727-3 - 1550 1550 -5 0 -31 -3* 26
T1/E1
Copper RJ-48
Single-Fiber
SM 20km - 8710-1 - - - 1310 1550 -15 -5 -30 -3 15
SM 40km - 8710-2 - - - 1310 1550 -8 0 -30 -3* 22
SM 20km - 8711-1 - - - 1550 1310 -15 -5 -30 -3 15
SM 40km - 8711-2 - - - 1550 1310 -8 0 -30 -3* 22
T1/E1
Coax + RJ-48
Single-Fiber
(2-slot module)
SM 20km - 8730-1 - - - 1310 1550 -15 -5 -30 -3 15
SM 40km - 8730-2 - - - 1310 1550 -8 0 -30 -3* 22
SM 20km - 8731-1 - - - 1550 1310 -15 -5 -30 -3 15
SM 40km - 8731-2 - - - 1550 1310 -8 0 -30 -3* 22
For wide temperature (-40 to 60
°
C), add a “W” to the end of the model number. Consult factory for extended temperature (-40 to +75
°
C) models.
When using single-ber (SF) media converter models, the Tx wavelength on the end has to match the Rx wavelength on the other.
*A minimum of 3dB of attenuation is required for these models.
**See SFP data sheet under Fast Ethernet for supported transceiever models.
Standalone Module Model Numbers