iConverter User Manual

4.2.10 cNode Loopback
The GX/TM2 has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agent
recognizes measurement packets and loops them back to the sending cNode device. Iometrix cNode
equipment is required to obtain performance metrics.
cNode configuration is accessed by selecting option 10 from the Port configuration screen.
PI SA
cNode Control -iConverter GX/TM2 iConverter, Serial Agent
Identifier -
Chassis Number = 1 Slot Number = 2 Model Number = 8923N-1
1: cNode Loopback Disabled
2: cNode Rate Limit 64 Kbps
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
From the menu, loopback can be enabled or disabled and the rate limit can be selected.
4.2.11 Port Statistics
The GX/TM2 module provides port statistics on both the fiber and UTP port.
The Port Statistics can be viewed by selecting option P from the Module configuration screen.
PI
Module - iConverter GX/TM2 iConverter, Serial Agent
Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual
Slot Number = 7 1: Port 1 Manual Port 1 AN Off Off
Model Number = 8939N-0 2: Port 2 Manual Port 2 AN Off Off
3: Port 2 10/100 Port 2 1000 Off Off
Serial Number = xxxxxxxx 4: Port 2 10 Port 2 100 Off Off
Manufacturing Date = xxxxxxxx 5: Port 2 HDX Port 2 FDX Off Off
Product Revision = xx 6: Link Propagate Link Segment Off Off
Software Revision = xx 7: Remote Fault Normal Off Off
8: Symm Fault Det Normal Off Off
LED 9: BP A Enabled BP A Disabled On On
1: Power = On 10: BP B Enabled BP B Disabled On On
2: Power Supply 1 = Off 11: Slave Only Master/Slave Off Off
3: Power Supply 2 = On 12: Not Available
4: Power Supply 3 = Off Configuration Setting
5: Port 1 Link = Off 13: Pause Function Disabled
6: BP Master = On 14: Not Available
7: UTP 100+10 Link = Off 15: Not Available
8: UTP 1000+10 Link= Off 16: Not Available
9: UTP FDX = Off 17: IP Protocol State Off
18: Management Mode ah OAM
Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl > P
Page 43