4.1.2 Module Management Mode (Configuration Setting 17 and 18)
From the Module configuration screen, the management mode can be changed. Select option 18 to change
the mode. The management mode options will be displayed.
PI
Module - iConverter GX/TM2 iConverter, Serial Agent
Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual
Slot Number = 7 1: Port 1 Manual Port 1 AN Off Off
Model Number = 8939N-0 2: Port 2 Manual Port 2 AN Off Off
3: Port 2 10/100 Port 2 1000 Off Off
Serial Number = xxxxxxxx 4: Port 2 10 Port 2 100 Off Off
Manufacturing Date = xxxxxxxx 5: Port 2 HDX Port 2 FDX Off Off
Product Revision = xx 6: Link Propagate Link Segment Off Off
Software Revision = xx 7: Remote Fault Normal Off Off
8: Symm Fault Det Normal Off Off
LED 9: BP A Enabled BP A Disabled On On
1: Power = On 10: BP B Enabled BP B Disabled On On
2: Power Supply 1 = Off 11: Slave Only Master/Slave Off Off
3: Power Supply 2 = On 12: Not Available
4: Power Supply 3 = Off Configuration Setting
5: Port 1 Link = Off 13: Pause Function Disabled
6: BP Master = On 14: Not Available
7: UTP 100+10 Link = Off 15: Not Available
8: UTP 1000+10 Link= Off 16: Not Available
9: UTP FDX = Off 17: IP Protocol State Off
18: Management Mode ah OAM
Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3
The GX/TM2 module supports several management options. Option 18 configures how the module will
communicate to its remote partner. ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses
Omnitron’s proprietary secure encrypted management channel. ‘Auto Secure OAM’ will force the remote
partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to
communicate with the remote partner over the secure protocol. The management channel can support IP or
IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17. ‘Auto ah OAM’
(option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification. ‘Auto ah OAM’ will
force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to
communicate with the remote partner over the ah protocol. This option provides an industry standard
method of fault detection and monitoring. The management channel supports both IP and IP-less connectivity
based on the configuration, option 17 and 18.
NOTE: See the NetOutlook user manual for complete information on the management modes.