Media Converter and Network Interface Device User Manual
Management Options iConverter, Serial Agent
Network Management
1: Chassis and Module Management
2: Set Module Identifier
Management Module Preferences
3: IP and Control Preferences
4: SNMP Preferences
5: Abandon Preference Changes
6: Save Preference Changes
7: Restore to Factory Defaults
8: Restart Management Module
9: Other Networking Features
Management Module Maintenance
10: Firmware Update
11: Set Date/Time
IP Address = 192.168.1.220
Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 9
Other Networking Features Screen iConverter, Serial Agent
1: Enable/Disable DHCP Client Disabled
2: Enable/Disable Keep Alive Trap Disabled
3: Keep Alive Trap interval (10-600 secs) 10
4: Enable/Disable SW1 Switch Block Enabled
5: Serial Baud Rate 57600 bps
6: Enable/Disable VLAN Support Disabled
7: VLAN ID (0-4095) 2
8: VLAN Priority (0-7) 7
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts
to enable DHCP.
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.
3.4.1.3 Setting the Chassis Number and Name
A Chassis Name, or sysName, can be assigned for identification of the 10/100M in the SNMP client. The
name can be any 1-32 character alphanumeric string.
The Chassis Number can remain as 1 (factory default) when the 10/100M is installed without an iConverter
NMM in the same chassis. When the 10/100M is installed in the same chassis as an NMM, then the 10/100M
must be set to the Chassis Number of the NMM.
To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow
the instructions to enter the chassis number.
To set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow
the instructions to enter the chassis name.
Page 14