Media Converter and Network Interface Device User Manual

3.4 CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE
To configure, attach the 10/100M to a DB-9 serial (RS-232) equipped computer with terminal emulation
software such as HyperTerminal. The 10/100M Serial Console Port (DCE) is a mini DIN-6 female connector
which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a
serial cable to the serial port of the PC and the Serial Console Port of the 10/100M. This is a standard
asynchronous serial interface. The pin-outs are illustrated below.
Serial Connector Pin Outs
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window.
Set the PC’s serial port to the following:
Bits Per Second: 57,600
Stop Bits: 1
Data Bits: 8
Parity: NONE
Hardware Flow Control: NONE
Power the chassis containing the 10/100M module and press <ENTER> to bring up a command line prompt
on the attached PC.
The module is configured with the following defaults:
IP
IP Address: 192.168.1.220
IP Subnet Mask: 255.255.255.0
Passwords
Serial: No password assigned
FTP: No password assigned
Telnet: public
SNMPv1/v2c Communities
READ: public
WRITE: public
SNMPv3 Parameters
User 1 name (read only): guest
User 2 name (read/write): admin
User 1 Privacy pwd: publicguest User 1 Authen pwd: publicguest
User 2 Privacy pwd: privateadmin User 2 Authen pwd: privateadmin
Page 11