6.0 SPECIFICATIONS
Chassis Type AC Powered Chassis 24VDC Powered Chassis 48VDC Powered Chassis
Module Capacity 18
Input Power Requirements
(typical)
Connector
100 to 240VAC 50 to 60Hz
0.4A @ 120VAC
IEC320
+/- 18 to 36VDC
2.0A @ 24VDC
3-pin Terminal
+/- 36 to 60VDC
1.0A @ 48VDC
3-pin Terminal
Compliances UL, cUL, CE, FCC Class A
Temperature
Standard Operating: 0 to 50°C
Wide Operating: -40 to 60°C
Storage: -40 to 80°C
Dimensions W: 17.5” x D: 9.5” x H: 2.5”
Weight 7.20 lbs.
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
MTBF (hrs) 526,000 486,000 1,081,000
7.0 CUSTOMER SUPPORT INFORMATION
If you encounter problems while installing this product, contact Omnitron Technical Support:
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology Dr.
Irvine, CA 92618, USA
Email: support@omnitron-systems.com
URL: www.omnitron-systems.com
040-01020-001B 05/12