User's Manual
PI SA
IP and Control Preferences Screen iConverter, Serial Agent
 1: Set IP 192.168.1.220
 2: Set Subnet Mask 255.255.255.0
 3: Set Gateway 192.168.1.1
 4: Chassis Number 1
 5: Chassis Name (also sysName) GX/TM2
 6: Enable/Disable TELNET Enabled
 7: Enable/Disable FTP Disabled
 8: Enable/Disable Soft Switch Reload Disabled
 9: TELNET Password *****
 10: FTP Password
 11: Serial Password
 Enter Choice, Management Options Screen(0), (H)elp, E(x)it >6
Disable TELNET (Y/N)?>
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.
The GX/TM2 may be accessed and configured via Telnet using any standard Telnet client. Only one Telnet
session can be active at a time. An inactive Telnet session terminates automatically after 5 minutes.
3.4.4.3 Updating the GX/TM2 Firmware via the Serial Console Port
To update the GX/TM2 firmware from the Serial Console Port, select 10 at the Management Options
screen, press <ENTER>. The GX/TM2 will display the following:
PI SA
Management Options iConverter, Serial Agent
 Network Management
 1: Chassis and Module Management
 2: Set Module Identifier
 Management Module Preferences
 3: IP and Control Preferences
 4: SNMP Preferences
 5: Abandon Preference Changes
 6: Save Preference Changes
 7: Restore to Factory Defaults
 8: Restart Management Module
 9: Other Networking Features
 Management Module Maintenance
 10: Firmware Update
 11: Set Date/Time
 IP Address = 192.168.1.220
 Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 10
UPDATE: Are you sure? (Y/N) > Y
Please Xmodem file now:
From the terminal program, use the Xmodem protocol to send the new GXTM-xxx.bin firmware file to the
GX/TM2 module (where xxx represents the release level of the software).
Once the file transfer begins, the data uploads to the GX/TM2. The process takes about five minutes over
a serial connection.