Owner's manual

Page 7
3.0 SITE PREPARATION AND INSTALLATION
3.1 AC Powered Chassis Site Preparation
Power source should be available within 5 ft. of the chassis and installed per the
National Electrical Code ANSI/NFPA-70.
This equipment requires a 100-240VAC, 0.5Amp, 50/60Hz power outlet. Appropriate
overloading protection should be provided on the AC power source outlets utilized.
The standard operating temperature of this equipment is 0 to 50 degrees C. If installed
in a closed or multi-module rack assembly, the operating ambient temperature of
the rack must not exceed the maximum rated 50 degrees C. See specications on
page 10 for wide temperature ranges.
Installation of the equipment should be such that the air ow in the front, back and
side vents of the chassis are not compromised or restricted.
Never use this equipment to carry any weight except its own. Never use it as a
shelf to support the weight of other equipment.
3.2 AC Powered Chassis Mounting
Attach the AC power cords to the back of the Power Receptacle and plug into the
AC outlet. Any installed iConverter modules will illuminate the power LED.
Fig. 6 Rear of 2-Module Chassis with Power Cord
3.3 DC Powered Chassis Site Preparation
Power source should be available within 5 ft. of the chassis. The over current protec-
tion for connection with centralized DC shall be provided in the building installation,
and shall be a UL listed circuit breaker rated 20 Amps, and installed per the National
Electrical Code, ANSI/NFPA-70.
This equipment requires 18-60VDC/1.0Amp (8235) or 2.0Amp (8236) rated power.
Appropriate overloading protection should be provided on the DC power source
outlets utilized.
WARNING: OnlyaDC power source that complies with
safety extra low voltage (SELV) requirements can be
connected to the DC-input power supply.