iConverter® 1-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514
Warning The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this module other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems Technology, Inc. Caution iConverter 1-Module Power Chassis User Manual 1.
2.0 INSTALLATION 2.3 DC Powered Chassis Site Preparation 2.1 Installing Module Power source should be available within 5 ft. of the chassis. The over current protection for connection with centralized DC shall be provided in the building installation, and shall be a UL listed circuit breaker rated 20 Amps, and installed per the National Electrical Code, ANSI/NFPA-70. Carefully slide the module into the open slot in the chassis.
WARNING: Note the wire colors used in making the positive, negative and ground connections. Use the same color assignment for the connection at the circuit breaker. Connect the power wires to the circuit breaker and switch the circuit breaker ON. If any modules are installed, their Power LED should indicate the presence of power. If installing with the NEBS Mounting Kit for 8242-9 and 8243-9 models, secure the grounding wire to the ground lug. See Figure 3 for the location of the grounding lug. 3.