User Manual

4.3.8 cNode Loopback
The GX/TM has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agent
recognizes measurement packets and loops them back to the sending cNode device. Iometrix cNode
equipment is required to obtain performance metrics.
cNode configuration is accessed by selecting option 10 from the Port configuration screen.
PI SA
cNode Control -iConverter GX/TM iConverter, Serial Agent
Identifier -
Chassis Number = 1 Slot Number = 3 Model Number = 8923-1
1: cNode Loopback Disabled
2: cNode Rate Limit 64 Kbps
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
From the menu, loopback can be enabled or disabled and the rate limit can be selected.
4.3.9 Port Statistics
The GX/TM module provides port statistics on both the fiber and UTP port.
The Port Statistics can be viewed by selecting option P from the Module configuration screen.
PI
Module - iConverter GX/TM iConverter, Serial Agent
Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual
Slot Number = 2 1: Fiber Manual Fiber AN Off Off
Model Number = 8923-1 2: UTP Manual UTP Auto-Neg Off Off
3: UTP 10/100 UTP 1000 Off Off
Serial Number = xxxxxxxx 4: UTP 10 Mbps UTP 100 Mbps Off Off
Manufacturing Date = xxxxxxxx 5: UTP HDX UTP FDX Off Off
Hardware Revision = xx 6: Link Propagate Link Segment Off Off
Software Revision = xx 7: Remote Fault Normal Off Off
8: Symm Fault Det Normal Off Off
LED 9: BP A Enabled BP A Disabled Off Off
1: Power = On 10: BP B Enabled BP B Disabled Off Off
2: Power Supply 1 = Off 11: Pause Enabled Pause Disabled Off Off
3: Power Supply 2 = On 12: Slave Only Master/Slave Off Off
4: Power Supply 3 = Off 13: UTP Manual-X UTP Auto-X Off Off
5: Fiber Link = Off 14: UTP Crossover UTP Through Off Off
6: BP Master = Off 15: Not Available
7: UTP 100+10 Link = Off 16: Not Available
8: UTP 1000+10 Link= Off OAM settings:
9: UTP FDX = Off 17: IP Protocol State Off
18: Management Mode ah OAM
Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl > P
Page 43