User Manual

4.2 MODULE MANAGEMENT MODE
From the Module configuration screen, the management mode can be changed. Select option 18 to change
the mode. The management mode options will be displayed.
PI
Module - iConverter GX/TM iConverter, Serial Agent
Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual
Slot Number = 2 1: Fiber Manual Fiber AN Off Off
Model Number = 8923-1 2: UTP Manual UTP Auto-Neg Off Off
3: UTP 10/100 UTP 1000 Off Off
Serial Number = xxxxxxxx 4: UTP 10 Mbps UTP 100 Mbps Off Off
Manufacturing Date = xxxxxxxx 5: UTP HDX UTP FDX Off Off
Hardware Revision = xx 6: Link Propagate Link Segment Off Off
Software Revision = xx 7: Remote Fault Normal Off Off
8: Symm Fault Det Normal Off Off
LED 9: BP A Enabled BP A Disabled Off Off
1: Power = On 10: BP B Enabled BP B Disabled Off Off
2: Power Supply 1 = Off 11: Pause Enabled Pause Disabled Off Off
3: Power Supply 2 = On 12: Slave Only Master/Slave Off Off
4: Power Supply 3 = Off 13: UTP Manual-X UTP Auto-X Off Off
5: Fiber Link = Off 14: UTP Crossover UTP Through Off Off
6: BP Master = Off 15: Not Available
7: UTP 100+10 Link = Off 16: Not Available
8: UTP 1000+10 Link= Off OAM settings:
9: UTP FDX = Off 17: IP Protocol State Off
18: Management Mode Auto ah
Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3
The GX/TM module supports several management options. Option 18 configures how the module will
communicate to its remote partner. ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses
Omnitron’s proprietary secure encrypted management channel. ‘Auto Secure OAM’ will force the remote
partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to
communicate with the remote partner over the secure protocol. The management channel can support IP or
IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17. ‘Auto ah OAM’
(option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification. ‘Auto ah OAM’ will
force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to
communicate with the remote partner over the ah protocol. This option provides an industry standard
method of fault detection and monitoring. The management channel supports both IP and IP-less connectivity
based on the configuration, option 17 and 18.
NOTE: See NetOutlook User Manual for complete information on the management modes.
Page 29