User Manual
PI
Module - iConverter GX/TM iConverter, Serial Agent
Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual
Slot Number = 2 1: Fiber Manual Fiber AN Off Off
Model Number = 8923-1 2: UTP Manual UTP Auto-Neg Off Off
3: UTP 10/100 UTP 1000 Off Off
Serial Number = xxxxxxxx 4: UTP 10 Mbps UTP 100 Mbps Off Off
Manufacturing Date = xxxxxxxx 5: UTP HDX UTP FDX Off Off
Hardware Revision = xx 6: Link Propagate Link Segment Off Off
Software Revision = xx 7: Remote Fault Normal Off Off
8: Symm Fault Det Normal Off Off
LED 9: BP A Enabled BP A Disabled Off Off
1: Power = On 10: BP B Enabled BP B Disabled Off Off
2: Power Supply 1 = Off 11: Pause Enabled Pause Disabled Off Off
3: Power Supply 2 = On 12: Slave Only Master/Slave Off Off
4: Power Supply 3 = Off 13: UTP Manual-X UTP Auto-X Off Off
5: Fiber Link = Off 14: UTP Crossover UTP Through Off Off
6: BP Master = Off 15: Not Available
7: UTP 100+10 Link = Off 16: Not Available
8: UTP 1000+10 Link= Off OAM settings:
9: UTP FDX = Off 17: IP Protocol State Off
18: Management Mode ah OAM
Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
The Module configuration screen provides general information concerning the configuration and status of
the module. The screen displays the model and serial numbers, hardware and software revisions, as well as
the condition of the LEDs and DIP-switches. The DIP-switches can be re-configured (options 1 -12)
without removing the module from the chassis. Select the appropriate option to change the DIP-switch
setting. Selecting DIP-switch options 1 - 12, will cause the selection to change states under the ‘Actual’
heading.
NOTE: The Plug-In Module configuration screen is shown. The standalone Module configuration
screen will display LED 2, 3, 4, and 6 and DIP-switches 9, 10 and 12 as NOT AVAILABLE.
Page 28