Hub/Switch Product Brochure
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • info@omnitron-systems.com • 140 Technology Dr. • Irvine, CA 92618
Trademarks are owned by their respective companies. iConverter and NetOutlook are registered trademarks of Omnitron Systems Technology, Inc.
Specifications subject to change without notice. ©2008 Omnitron Systems Technology, Inc. All rights reserved.
091-18000-001H 12/08
Alarms / Traps
• Warm Start
• Link Up/Down
• Chassis Insertion/Removal
• Authentication Failure
• DIP-Switch Configuration Change
• Software Configuration Change
• Temperature Out-of-Range
• Power Supply Out-of-Range
• Power Supply Insertion/Removal
• Chassis Reset
• Module Reset
• Module Insertion/Removal
• Port Link State Change
• Redundancy Primary Up/Down
• Redundancy Secondary Up/Down
• FTP Session Open/Close
• Telnet Session Open/Close
• Dying Gasp (Power Loss Trap)
Active Controls
• Link Propagate/Link Segment
• Remote Fault Detection
• Module Name
• Chassis Name and Number
• IP Address
• 802.3ah OAM Enable
• Secure IP-less OAM Enable
• Subnet Mask
• Gateway
• Management Port Disable
• Alarm Threshold Setting
• Download Software via FTP
• Reset Chassis
• Telnet
• Trap IPs
• FTP Enable
• Password Selection
• Soft Switch Reload
IP-less management requires an NMM in the core chassis, and
a media converter with integrated management installed at each
remote end of the IP-less managed link. An
iConverter
10/100M2
plug-in module is installed in the 19-Module chassis, and
connected via the fiber link to a standalone 10/100M2 Network
Interface Device (NID). This configuration enables the 19-Module
master chassis to establish an IP-less management channel
between the 10/100M2 link partners. The IP address
resides only at the network core, and does not exist on the
customer network.
Model Description
8000-0
iConverter NMM Module w/ Dying Gasp Support
8080-3
NMM Cascade Cable (3 ft.)
8081-3
NMM Serial Cable (DB-9, 3 ft.)
Model Type NMM
Protocols
IP, UDP, SNMPv1, SNMPv2c, SNMPv3,
Telnet, TCP, FTP, ARP, ICMP, 802.3ah
Connectors
RJ-45, DB-9
Controls
UTP cross-over, Frontplane / Backplane
LED Displays
Power, Power Supply (3), UTP link,
Master, Slave, Mgt. Poll
Supported MIBs
RFC1155, RFC1156, RFC1157,
RFC1212, RFC1213, OST MIB
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A, NEBS 3
Power Requirement
0.32A @ 3.3VDC (typical)
Temperature
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (hrs)
786,000
Chassis Information
• Part Number
• Serial Number
• Revision
• Description
Chassis Status
• Power Status
• Power Output Voltage
• Chassis Temperature
Module Status
• Module Power
• Link Status
• Active Port
• Diagnostic Status
• Management
Module Information
• Module Type
• Slot Occupied
• Part Number
• Serial Number
• Configuration
• Revision
• Ports on Module
• User-defined Identifier