User's Manual
UM-003-A OPS243-A User Manual  9  OmniPreSense Corporation 
Sampling Rate/Buffer Size (-A, -C Doppler only) – set these values to control the sample rate of the 
module.  This setting influences the output data and the rate at which the data is reported. The buffer 
size influences the report rate and resolution.  A buffer size of 512 will have a report rate between 5-30Hz. 
The resolution becomes worse by a factor of two with a 512-buffer size versus 1024 (Figure 6) and worse 
again at 256 buffer size. 
Command 
Name 
R/W 
Notes 
SI 
1K samples/second 
Write 
SV 
5K samples/second 
Write 
SX or S1 
10K samples/second 
Write 
S2 
20K samples/second 
Write 
SL 
50K samples/second 
Write 
SC 
100K samples/second 
Write 
S> 
1024 buffer size 
Write 
1024 samples are collected before processing 
S< 
512 buffer size 
Write 
512 samples are collected before processing 
S{ 
256 buffer size 
Write 
256 samples are collected before processing 
Figure 6. Doppler (-A) Buffer Size versus Resolution 
-0.10
0.10
0.30
0.50
0.70
0.90
1.10
1.30
1.50
1.70
1.90
2.10
2.30
2.50
 1,000  10,000  100,000
Resolution (m/s)
Sampling Rate
256 Buffer
512 Buffer
1024 Buffer