User's Manual
UM-003-A OPS243-A User Manual  17  OmniPreSense Corporation 
Magnitude Control – provides control over the sensitivity of the module to detect moving objects.  Low 
numbers are most sensitive, high numbers are least sensitive.  Magnitude is related to Squelch as the 
square root of the number.  For example, a magnitude setting of 10 is equal to a Squelch setting of 100 
(QI). 
Command 
Name 
R/W 
Value 
M? 
Current speed magnitude 
setting 
Read 
Doppler (-A, -C) radar only. 
m? 
Current range magnitude 
setting 
Read 
FMCW (-B, -C) radar only. 
M>n 
Low Speed Magnitude 
Filter 
Write 
n is any number upon which no detected 
magnitudes below that number will be 
reported. M>0 resets to no limit. Doppler (-A, 
-C) radar only. 
M<n 
High Speed Magnitude 
Filter 
Write 
n is any number upon which no detected 
magnitudes above that number will be 
reported. M<0 resets to no limit. Doppler (-A, 
-C) radar only. 
m>n 
Low Range Magnitude 
Filter 
Write 
n is any number upon which no detected 
magnitudes below that number will be 
reported. m>0 resets to no limit. FMCW (-B, -
C) radar only. 
m<n 
High Range Magnitude 
Filter 
Write 
n is any number upon which no detected 
magnitudes above that number will be 
reported. m<0 resets to no limit. FMCW (-B, -
C) radar only. 