Module/Transmit Power – set to control the operating mode (PA, PI, PP) or the transmit power. The 
typical maximum transmit power is 9 dB. Reducing the transmit power does not reduce the overall 
power consumption of the module. Note that the detection range will decrease with decreased 
transmit power. 
Command 
Name 
R/W 
Value 
P? 
Active Power State 
Read 
Reports current power state. 
PA 
Active Power Mode 
Write 
Normal operating mode. 
PI 
Idle Power Mode 
Write 
No activity, waits for Active Power command. 
The RF is powered down for further power 
savings. 
PP 
Single Pulse 
Write 
Use to capture and process a single pulse and 
buffer of data. Use when the sensor is set to 
PI mode. 
P7 or PN 
Transmit Power Control or 
Min Power 
Write 
Transmit is set at -9 dB below max power. 
P6 
Transmit Power Control 
Write 
Transmit is set at -6 dB below max power. 
P5 
Transmit Power Control 
Write 
Transmit is set at -4 dB below max power. 
P4 
Transmit Power Control 
Write 
Transmit is set at -2.5 dB below max power. 
P3 or PD 
Transmit Power Control or 
Mid Power 
Write 
Transmit is set at -1.4 dB below max power. 
P2 
Transmit Power Control 
Write 
Transmit is set at -0.8 dB below max power. 
P1 
Transmit Power Control 
Write 
Transmit is set at -0.4 dB below max power. 
P0 or PX 
Transmit Power Control or 
Max Power 
Write 
Transmit power is set at its maximum value 
with maximum range. PX has additional 
“overdrive” of 0.2 dB when utilized. 
PO 
Transmit Off 
Write 
Turn transmit off and put in sensor in receive 
only mode. Use P! to turn transmit back on. 
P! 
System Reset 
Write 
Full system reset including the clock. 