Data Output – set to control the data output. 
Command 
Name 
R/W 
Value 
OD 
Range Report 
Write 
Turn range reporting on or off. Default 
operation range is reported. Use Od to turn it 
off and OD to turn it back on. FMCW (-B, -C) 
radar only. 
OS 
Speed Report 
Write 
Turn speed reporting on or off. Default 
operation speed is reported. Use Os to turn it 
off and OS to turn it back on. Doppler (-A, -C) 
radar only. 
OF 
FFT Output On 
Write 
Results from the FFT processing of each buffer 
is sent. Data is output with json output 
format. Use Of to turn FFT output off. It’s not 
recommended to use OF with UART, especially 
at low baud rates. 
OG 
Object Sensor Light 
Write 
Enables White light when Object Sensor is 
enabled (IG) and an object is detected. Disable 
the light with Og. By default, the object sensor 
light is disabled. 
OC 
Processing Light Activity 
Write 
Enables lights showing processing activity. 
Disable the lights with Oc. By default, the 
processing activity lights are disabled. 
OJ 
JSON Mode On 
Write 
Turns on output to format data in JSON 
format. An example would output: 
{"speed":0.58, "direction":"inbound", 
“time”:105, :tick”:135}. Use Oj to turn off 
JSON mode. 