Instructions / Assembly
• 4 •
FILTER CARTRIDGE REPLACEMENT continued
C
1
3
2
TROUBLESHOOTING
Leaks between cap and bottom of housing:
1. Turn off water supply and press the red pressure-relief
button. Remove bottom of housing.
2. Clean O-ring and O-ring groove (located directly beneath
threads of housing). Lubricate O-ring with silicone grease
and replace securely into groove. Screw bottom of housing
onto cap and hand-tighten. DO NOT OVER-TIGHTEN
Leaks on inlet/outlet connections:
3. Turn off water supply and turn on faucet to release
pressure in pipes. Remove tubing from fitting (see Step
6 under Installation Instructions) and make sure end of
tubing is cut squarely and free of burrs. Reinsert tubing
into quick-connect fittings, making sure to push securely
until tubing hits a hard stop.
4. Turn on water supply. If leaks persist, or if there are other
leaks on system, turn off water supply. Call Customer
Service at 800.279.9404.
REPLACEMENT PARTS
1 144802 Pressure Relief Button Kit (not visible)
2 154371 Blue Cap
3 K4 O-ring
4 153219 Blue Housing Sump
5 OW30 Housing Wrench (not shown)
6 150580 Screw Kit (not shown)
For replacement parts call Customer Service at 800.279.9404.
2
1
3
4
IOWA Residents Only:
Store or seller’s name
Address
City State Zip Telephone
Seller’s Signature Date Customer’s Signature Date
13845 BISHOPS DR., SUITE 200, BROOKFIELD, WI 53005 U.S.A.
P. 262.238.400
|
CUSTOMER SERVICE: 800.279.9404
|
tech-support@pentair.com
|
pentair.com
All indicated Pentair trademarks and logos are property of Pentair. Third party registered and
unregistered trademarks and logos are the property of their respective owners.
© 2022 Pentair. All rights reserved. 4006748 Rev A AU22
For Pentair
Product Warranties visit: Pentair.com/assets/residential-ltration-warranty