Indoor Fireplace User Manual

16 Installation (for qualified installers only)
© Travis Industries 4090507 100-01217_000
Electrical Connection (required)
The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and
must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps).
Caution
: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation.