INSTALLATION & OPERATING INSTRUCTIONS GAS HOBS MODELS OG30XA, OG60XA, OG60WA, OG61XA, OG61WA, OG62XA, OG63XA, OG64XA, OG65XA, OG66XA, OG67XA, OG70XA, OG71XA, OG72XA, OG90XA, OG91XA, OG92XA, OGG64A, OGG75A, OGG96A
CONTENTS 1. 2. 3. 4. 5. 6. 7. INSTRUCTIONS FOR SAFE AND PROPER USE POSITIONING OF THE HOB GAS CONNECTION ELECTRICAL CONNECTION ADAPTI ON TO DIFFERENT TYPES OF GAS CLEANING AND MAINTENANCE WARRANTY 2 5,6 8 9 10 12 13 Thank you for choosing our product. We advise you to read this manual carefully. It contains all the necessary instructions for maintaining the appearance and functional qualities of the hob.
INTRODUCTION INSTRUCTIONS FOR SAFE AND PROPER USE This manual is an integral part of the appliance and therefore MUST be kept in its entirety and in an accessible place for the whole working life of the cooking hob. We advise reading this manual and all the instructions therein before using the cooking hob. Also, keep the series of nozzles (injectors) supplied. Installation MUST be carried out by an AUTHORISED PERSON in accordance with the Regulation in force.
INTRODUCTION DO NOT PUT pans without perfectly smooth and flat bottoms on the cooking hob grids. DO NOT USE kitchenware or griddle plates that extend beyond the external perimeter of the hob. THE HOB IS TO BE USED BY ADULTS ONLY. Do not let unsupervised children play with the hob. Replaced appliances MUST be taken to a special garbage collection centre. This appliance is designed for cooking food and it SHALL NOT BE USED AS A SPACE HEATER.
INTRODUCTION MARKINGS: include the following: (i) Gas Type Label: fixed to the underside of the appliance. (ii) Data plate: fixed to the underside of the appliance stating Model Number, AGA or SAI-GLOBAL Approval Number, Gas operating pressure, Nominal Gas Consumption etc. (iii) AGA or SAI-GLOBAL label fixed to the underside: showing that the appliance conforms to the Standards.
Natural gas: The regulator supplied MUST be fitted to the ½” thread on the elbow at the rear of the hot plate. The NG regulator MUST be checked and adjusted to 1.0k Pa after installation. ULPG: Can be connected directly with the inlet fitting. The pressure MUST be checked to ensure the supply to the appliance is operating at 2.75kPa. Clearance Above and Around Domestic Cookers: • 200mm from the edge of the burner to combustible materials on vertical sides of the appliance.
FIGURE 2. Clearance above and around domestic cookers Extract from AS5601 1 Overhead clearances - (Measurement A) Range hoods and exhaust fans shall be installed in accordance with the manufacturer's instructions. However, in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600mm or, for an overhead exhaust fan, 650mm.
2 Side clearances - (Measurements B & C) Where B, measured from the periphery of the nearest burner to any vertical combustible surface, is less than 200mm, the surface shall be protected in accordance with Clause 5.12.1.2. to a height C of not less than 150mm above the hob for the full dimension (width or depth) of the cooking surface area. Where the cooking appliance is fitted with a 'splashback', protection of the rear wall is not required.
GAS CONNECTION This appliances is suitable for installation with Natural Gas or ULPG Refer to page 11 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of ULPG appliances.
ELECTRICAL CONNECTION Any electrical writing MUST be carried in compliance with the local electrical authority regulations by a qualified electrician. The appliance has a 3 pin plug attached, to be plugged .into a 240Volt, 50HZ, single phase outlet. WARNING -ALL APPLIANCES MUST BE EARTHED: Omega Appliances cannot accept responsibility for any damage to persons or to property arising from faulty connection or non- connection to earth.
CHANGING GAS INJECTORS-CONVERSI ON OF GAS TYPE Your cooktop has been manufactured for operation on the gas type marked on the hob/carton. In some cases, it may be necessary to convert to convert the burners for use with another type of gas. 1) Replacement injectors are supplied with the appliance or they are available from Omega Appliances or it's agents. 2) All such work MUST be carried out by an Authorized Person. 3) Isolate the electrical supply from the appliance. 4) Remove burner cap and burner skirt.
FIGURE 4 & 5 ig. 5 NOMINAL GAS CONSUMPTI ON Gas Type; Natural Gas MJ/h - NG (1.00 kPa) Burner Injector size mm Small .90 Medium 1.15 3.6 6.3 Large 1.55 10.8 Wok 1.75 Fish 1.55 13.2 10.8 Burner Injector size mm MJ/h - NG (2.75 kPa) Small 0.55 4.0 Medium 0.66 6.3 Large Wok 0.85 0.98 Fish 0.85 10.2 12.6 10.2 ULPG 11 . .
MAINTENANCE AND CARE: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.