10.2.4- JUMPERS CONFIGURATION
Function Close Jumper
220 Ω terminator resistor for the RS422 JP1 (By default opened)
switch debounce of 5 Hz for the STOP line JP2* (By default closed)
switch debounce of 5 Hz for the START line JP3* (By default closed)
switch debounce of 5 Hz for the RESET line JP4* (By default closed)
10.2.5- SERIAL DATA OUTPUT CONFIGURATION
* = Factory set-up
* = Data output format only when the colon is lighted.
** = Data output format only when the colon is NOT lighted.
H = Character from "0" to "9" which represent one number of hours.
M = Character from "0" to "9" which represent one number of minutes.
S = Character from "0" to "9" which represent one number of seconds.
Character "." = 02E hex.
Character "-" = 02D hex.
Character "(NUL)" = 0 hex.
Character "(CR)" = 0D hex.
Jumper Application A Jumper position B
JP5 for STOP line 1 KΩ pull-up * 1 KΩ pull-down
JP6 for START line falling edge/low level active* rising edge/high level active
JP7 for STOP line falling edge/low level active* rising edge/high level active
JP8 for RESET line falling edge/low level active* rising edge/high level active
JP9 for START line 1 KΩ pull-up* 1 KΩ pull-down
JP10 for RESET line 1 KΩ pull-up* 1 KΩ pull-down
Data output format
with DIP switch 7 with DIP switch 7
in position ON in position OFF
(NEWPORT mode) Standard mode
C2 HHM.MS.S(CR) HH.MM.SS(CR) --(NUL)--(NUL)--(CR)
C1 HHM.M(CR) HH.MM(CR) * --(NUL)--(CR)
HH(NUL)MM(CR)**
C0 MMS.S(CR) MM.SS(CR) --(NUL)--(CR)
Instrument
reference
Transmission during
time adjust or in
alarm status