Products, Inc Weather Radio User Manual
64
CE APPROVAL INFORMATION
1. Electromagnetic Compatibility (EMC)
This device conforms with requirements of EMC Directive 89/336/EEC,
amended by 93/68/EEC. This instrument complies with the following EMC
Immunity Standards as tested per EN 61326-2:1998 (Industrial Locations)
Phenomena Test Specification Basic Standard
Electrostatic +/- 4 kV contact discharge IEC 1000-4-2
Discharge +/- 8 kV air discharge Performance
Criteria B
Radio Frequency 27 - 1000 MHz IEC 1000-4-3
electromagnetic 3 V/m Performance
field. 80% AM (1 KHz) Criteria A
Fast Transients +/- 2 kV (ac mains) IEC 1000-4-4
+/- 1 kV (dc, signal I/O) Performance
5/50 ns Tr/Th, 5 KHz rep. freq. Criteria B
Surge +/- 1.0 kV AC Port L-L IEC 1000-4-5
+/- 2.0 kV AC Port L-PE Performance
+/- 1.0 kV DC Port L-L Criteria B
+/- 2.0 kV DC Port L-PE
Radio Frequency 0.15 - 80 MHz IEC 1000-4-6
conducted3 VrmsPerformance
80% AM (1 KHz) Criteria A
This instrument complies with the following EMC Emission Standards as
tested per EN 61326-2:1998 (Class B equipment)
Phenomena Frequency Limits Basic
Range Standard
Radiated 30-230 MHz 30 dB_V/m at 10 m CISPR 22
Emission 230-1000 MHz 37 dB_V/m at 10 m Class B
quasi peak
Conducted 0.15-0.5 MHz 66-56 dB_V quasi peak CISPR 22
Emission 0.5-5 MHz 56 dB_V quasi peak Class B
5-30 MHz 60 dB_V quasi peak
2.Safety
This device conforms with Low Voltage Directive 73/23/EEC, amended by 93/68/EEC.
The following LVD requirements have been met to comply with EN 61010-1, 1993
(Electrical equipment for measurement, control and laboratory use)
1. Pollution Degree 2
2. Installation Category II
3. Class I Equipment (100-240 Vac Powered Units)