Owner's manual
5
Fuse Rating: internal resettable 1.6A fuse protects the electronics on the power
input.
Polarity Protection: internal rectifier circuit protects from reversed polarity on the
power input.
Operating Temperature: 0
F
C (32
F
F) to 50
F
(122
F
F).
d.1 CE Compliance
Any model FSV10 bearing a CE marking on it, is in compliance with the
below stated test standards currently accepted.
EMC Compliance with 89/336/EEC as amended;
Emission Standard: EN 55011:1991, Group 1, Class A
Immunity Standard: EN 55082 2:1995
(e) OPERATING INSTRUCTIONS
CAUTION: If the valve is left in the active mode for an extended
period of time, it may become warm or even hot to the touch.
Use care in avoiding direct contact with the valve during operation.
e.1 Preparation
It is assumed that the FSV10 has been correctly installed as described in
section (b). Turn the DC power source ON. A pilot light on the front of the
FSV10 will illuminate indicating the device is active.
e.2 Maximum Output Voltage to Valve
As shown in Figure e-1, remove the square plug of the FSV10 for the
access window. Position 1, 2, and 3 on the header block determine the
maximum output voltage supplied to the valve. The factory default setting
is 22 VDC (position 2).
ACCESS WINDOW
9-PIN "D"
SUB-CONNECTOR
DC POWER
JACK
1 2 3 4 5
1
6
5
9