Product Manual
SET UP
(RefertoFigure1&2)
1.Remove the plugonoil port, connect 3/8" NPTF
hydraulicconnectiontooilport,i.e.coupler,hydraulic
hose,tting etc. Ensurethe oil ports and thread
connections are clean before connecting to the
hydraulic system.
NOTE: Alwayssecurethreadedconnectionswithnon-
hardening pipe thread compound. Take care not to
introducecompoundintoportorices.Tightensecurely
to prevent accidental removal of components while in
use.
2. Connect the hydraulic connection to hydraulic pump.
3. Install a pressure gauge to monitor the system
pressure.
WARNING: DO NOT exceed rated pressure of
10,000 psi.
3
Figure 2 - Typical Installation Illustration
Bead Breaker
*Hydraulic Connections
i.e.Couplersandtting
(3/8"-18NPTF)
*AirActuated
Hydraulic Pump
*Hydraulic Hose
AirSupplyInlet
(*)Itemsnotincludedwithunit
BEFORE USE
1. Verify that the product and the application are
compatible,ifindoubtcallOmegaTechnicalService
(888)332-6419.
2.Beforeusingthisproduct,readtheoperator'smanual
completely and familiarize yourself thoroughly with
the product, its components and recognize the
potential hazards associated with its use.
3. Replace worn or damaged parts and assemblies with
factory authorized replacement parts only.Lubricate
asinstructedinMaintenanceSection.
4. Use adequate eye protection when operating or near
this equipment.
!