User manual

DBK Option Cards and Modules User’s Manual 987693 DBK Setup in LogView 4-3
DBK Reference for LogView Users
DBK Description Type Comment
DBK207 16-Channel, 5B Carrier Board P1-ANALOG Not used with LogBook.
DBK207/
CJC
DBK207 with Cold Junction
Compensation
P1-ANALOG Not used with LogBook.
DBK208 Relay Carrier Board, Opto-22 Compatible P2-DIGITAL Not used with LogBook.
DBK209 P4-to-P1/P2/P3 Mini-Adapter Board Interface Not used with LogBook.
DBK210 Grayhill
TM
70M-Series Mini-Module
Carrier Board.
P2-DIGITAL Not used with LogBook.
DBK213 Screw-Terminal & Exp. Card Module Interface Not used with LogBook.
DBK214 16-Connector BNC Interface Module Interface Not used with LogBook.
DBK215 16-Connector BNC Connection Module Interface Not used with LogBook.
DBK601
thru
DBK609
Rear Panels for use with DaqBoard/260,
DBK60, and LogBook/360.
Connector
Panels
No configuration in LogView.
SPECIAL CASES – DBK Recognition in LogView for DBK48, 55, 65, and 85
LogView does not include the means to directly select the following DBK options. However, these DBKs will
still function fine with LogBook and LogView. To do so we get the system to recognize these devices by
selecting a different, but related DBK option.
DBK48
16-Slot 8B Signal Conditioning Module
To use a DBK48 and its 8B modules with LogBook: Select DBK42 in LogView. This will recognize the
DBK48, but will identify it as a DBK42. For each 8B module, select the 5B module that exhibits the same
measurement ranges; three examples follow:
For SC-8B30-01 select SC-5B30-01 as both have an Input Range of ±10 mV; and an Output Range of ±5V.
For SC-8B34-02
select SC-5B34-02 as both are Type 100 Ohm Pt; with an Input Range of 0°C to +100°C.
For SC-8B47-T-07
select SC-5B47-T-07 as both are a Type T Thermocouple, with an Input Range of 0°C to +200°C.
DBK55
8-Ch. Frequency to Voltage Input Module
A single DBK55 has the functionality of two DBK7 cards. When using a DBK55 with LogBook, select
DBK7 in LogView. This will recognize the DBK55, but will identify it as a DBK7. Next do one of the
following, as applicable:
(a) If the DBK55 is set to the L sub-address, Select DBK7 (0) and DBK7 (1)
(b) If the DBK55 is set to the H sub-address, Select DBK7 (2) and DBK7 (3)
DBK65
8-Ch. Transducer Interface Module
To use a DBK65 with LogBook: First select DBK80 in LogView. This will recognize the DBK65, but will
identify it as a DBK80 (which has eight additional channels). Next do one of the following as applicable:
(a) If the DBK65 is set to the L sub-address, use channels 0 through 7; and ignore the displayed
unused channels (8 through 15).
(b) If the DBK65 is set to the H sub-address, use channels 8 through 15; and ignore the displayed
unused channels (0 through 7).
DBK85
16-Ch. Differential Voltage Module
To use a DBK85 with LogBook, select DBK80. This will recognize the DBK85, but will identify it as a
DBK80.