Setting Internal Clock Speed to 100 kHz
This section applies to DaqView users who are using one or more of the following DBK options in
conjunction with a DaqBook/2000 Series Device, DaqBoard/2000, DaqBoard/2001, DaqBoard/2005 or a
compact PCI counterpart of these boards; i.e., cPCI DaqBoard/2000c, cPCI DaqBoard/2001c, and cPCI
DaqBoard/2005c.
DBKs impacted at the time of this writing are: DBK12, DBK13, DBK15, DBK19, DBK52, DBK53, and
DBK54.
Note: In DaqView’s Configure Systems Hardware window, after selecting DBK12, DBK13, DBK15,
DBK19, DBK52, DBK53, or DBK54 a message box should prompt you to select an internal clock
speed of 100 kHz.
A Message Box Regarding Specific DBKs and the 100 kHz Internal Clock Speed Setting
To select an “Internal Clock Speed” of 100 kHz:
1. Select the Acquisition Setup tab on DaqView’s main window.
2. On the lower left corner of the window, under Scan Configuration,
click the Preferences button.
The Advanced Options window will appear (following figure).
Note: The Advanced Options box can also be accessed from the
Windows pull-down menu.
3. Under “Internal Clock Speed,”
select 100 kHz.
4. Click the OK button to return to
DaqView’s main window.
The internal clock is now set for
100 kHz.
3-8 DBK Setup in DaqView 968194 DBK Option Cards and Modules User’s Manual