em WMS-22A and WMS-22 @fl Current Loop Wind Stations * WMS-22A Wind Speed indicator WMS-22 Wind Speed and Direction Indicator Operator ’s Manual
Unpacking Instructions Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses): 0 WMS-22A or WMS-22 ”. Wind Sensor 0 Transmitter Housing Assembly, with I/O connection terminal strips _-_ l Operator’s Manual If you have any questions about the shipment, please call the OMEGA Customer Service Department. When you receive the shipment, inspect the container and equipment for signs of damage. Note any evidence of rough handling in transit.
Servicing USA and Canada: Call OMEGA Toll Free USA Canada One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Lava1 (Quebec) H7L 5Al Telephone: (203) 359-1660 Telephone: (514) 856-6928 FAX: (203) 359-7700 FAX: (514) 856-6886 Sales Service: l-800-826-6342 / l-SOO-TC-OMEGASM Customer Service: l-800-622-2378 / l-SOO-622-BESTSM Engineering Service: l-800-872-9436 / l-SOO-USA-WHENSM TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Servicing Europe: United Kingdom Sales and Distribution Center 25 Swanningt
OMEGA Engineering Model WMS-22 and WMS-22A Current Loop WindStations Instruction Manual 1.0 INTRODUCTION The WMS-22 Current Loop WindStation measures wind speed and direction and converts each paramenter into 4-20 mA output signals for use by process control or monitoring systems. No external power is required since the encoding electronics for wind speed and for wind direction are isolated and powered from their respective 2-wire current loops.
2.3 Specifications Wind Speed Measurement Range Averaging Interval Resolution Threshold Measurement Accuracy O-100 mph 2.1 Seconds 1 mph
4.2 Wind Sensor Installation Choose the mounting location for the wind sensor and temperature sensor unit which is free from obstructions. Use extreme care to prevent contact with electrical power lines while erecting the unit. A typical installation will position the wind sensor approximately 10 meters above the highest obstacle within a 300 meter radius of the mounting locations. Position the WMS-22 sensor on the end of a 1” diameter TV mast tubing or a 314” Schedule 40 pipe.
Connect the test leads of a digital voltmeter across the resistor to measure the plc lo.9 current. The measured wind speed and direction at several cardinal calibration points should correspond to the following: Wind Direction I Wind Speed (mph) V 1000 (Volts) N+ 0.0 4.0 0.4 NE = 45 ” 12.5 6.0 0.6 E = 90 ” 25 8.0 0.8 SE = 135 ” 37.5 10.0 1.0 S = 180 ” 50 12.0 1.2 SW = 225 ” I W = 270” NW = 315” I Loop Current (mA) N- I 62.5 I 14.0 I 1.4 75 16.0 1.6 87.5 18.0 1.
I5 + + l- DC PO SOURC 10 o l 48 MOD CURREN TYP I CA L W I R I NG E L Z OO T L OO P W I T HAS -W S -2 2 W I NDS TAT I NG L E PO W ER E - TYPICAL LO PRODUCES OU VDC IO N W ER SOURC E
L = Ei- I- IJ I I II --
WARRANTY ree of defects in mat satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation.
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...