User's Manual
PHYSICALDIMENSIONS
All dimensions in inches (mm)
SpecicationsliabletochangewithoutpriorwarningDataSheet-Issue03L08/2013SLAppliestoOM-EL-WiFi-TCPage2of2
* Dependant on transmission rate, may be less with frequent transmissions
Warning - do not exceed operating temperatures
www.omega.com
The OM-EL-WiFi-TCis a low poweredbattery device. When congured using typical transmission periods (e.g. once every hour) the sensor will
operate for up to one year (at room temperature). The battery can then be recharged via a PC or USB +5V wall adapter using the USB lead provided
or can be permanently powered by the USB wall adapter.
The software installed on the PC will allow set-up, data logging and data review. Set-up features will include sensor name, °C/°F, sample rate, and
high/lowalarms.Oncecongured,historicdatacanbeviewedviathegraphingtoolorexportedintoExcel.Thissoftwareisavailabletodownload
for free from www.omega.com.
The sensor is a freestanding unit, however, it can be attached to a wall or vertical surface using the bracket and screws / sticky pad provided.
Itis supplied with a thermocouple probewithan attachmentso thatit canbe securelyxedtoat surfaces. It is perfect fora wide range of
temperature monitoring situations e.g. manufacturing processes, cold/hot storage and laboratory conditions. The probe is removable so alternatives
canalsobeusedtomeetspecicrequirementsprovidingtheyoperatewithinthesametemperaturerange.TheOM-EL-WiFi-TCsupportsJ,K,Nand
T thermocouple probes.
Specications Minimum Typical Maximum Unit
Battery life
1* Year
USB supply voltage
4.5 5 5.5 Vdc
Operating temperature range (sensor only)
-20 (-4) +60 (+140) °C (°F)
Loggingperiod(usercongurable)
10 sec 10 min 12 hrs
Transmissionperiod(usercongurable) 1 min 1 hr 24 hrs
Temperature measurement range (probe dependent) -270 (-454) +1300 (+2372)
°C (°F)
Temperature measurement resolution
0.1 °C
Temperature display resolution (-99.9 to 999.9°C) 0.1 °C
Temperature accuracy (probe dependent) ±1.5 °C
3.83” (97.3)
1.03” (26.36)
2.80” (71.3)