Operation
Maintenance
CHECKING THE EFFICIENCY OF THE STOP PUSHBUTTON
While the machine is connected to the power supply and the utensil is moving press the pushbutton.
START UP
Set the differential switch tted upstream at “I”. The light indicator will light up, indicating that the machine is
powered.
Press the start pushbutton to start the machine.
NOTE
If the presser is in an “open” position the machine will not run, therefore it will have to be lowered.
STOP
Press the stop pushbutton to stop the running of the machine; the light indicator will remain on to indicate
that the machine is powered.
Then set the differential switch installed upstream at “0”, in this way disconnecting the machine.
NOTE
Each time a work shift nishes or the machine is left to rest, the differential switch must be left set at “0”.
USING THE SIEVE
The extractable sieve “1” in stainless steel enables obtaining a uniformly grated product, avoiding sieving. It
must be requested upon ordering the machine.
ATTENTION!
Every maintenance and cleaning operation on the grater must only be done with the machine at a standstill,
disconnected from the power supply. The area where maintenance operations are carried out must always be
kept clean and dry. Do not allow unauthorized personnel to work on the machine. Any replacement of parts
must be made with original spare parts at authorized work shops or directly by the manufacturer.
ATTENTION!
Disconnect the machine from the electrical supply before cleaning it. Do not clean the machine with jets of
water. Only use non-toxic detergents, designated for cleaning components for use with food products.
PUTTING OUT OF ORDER
The machine is made of materials such as aluminum, steel and copper; therefore they do not require particular